British Columbia WorkSafeBC Heat Exposure Standard (OHS Guideline G7.28) — Heat Stress Work/Rest Limits

British Columbia WorkSafeBC heat exposure standard (OHS Guideline G7.28). Adopts ACGIH TLV/AL WBGT thresholds as the regulatory benchmark. Requires an Exposure Control Plan when thresholds are approached or exceeded.

Browse all standards → · Evaluate every standard at once in the calculator →

Governing metric
WBGT (°C) by workload and acclimatization status
Authority
WorkSafeBC (British Columbia, Canada)
Jurisdiction
British Columbia Canada
Legal status
Regulation
In force since
1999-08
Rule type
Schedule Engine
Standard ID
HGC-060

Check a reading against this rule

The drag-to-check calculator needs JavaScript. Every value it can show is a row of the table below, which is computed by the same engine.

Governing formula

No standalone formula is published for this standard; see programmable logic and parameters below.

Work/rest limits

Acclimatized workers

WBGT (°C)Light
180 W
Moderate
300 W
Heavy
415 W
Very heavy
520 W
2475–100% Work75–100% Work50–75% Work25–50% Work
2575–100% Work75–100% Work50–75% Work25–50% Work
2675–100% Work75–100% Work50–75% Work25–50% Work
2775–100% Work75–100% Work50–75% Work25–50% Work
2875–100% Work75–100% Work25–50% Work25–50% Work
2975–100% Work50–75% Work25–50% Work0–25% Work
3075–100% Work25–50% Work0–25% Work0–25% Work
3175–100% Work0–25% WorkExceeds screening criteriaExceeds screening criteria
3225–50% WorkExceeds screening criteriaExceeds screening criteriaExceeds screening criteria
33Exceeds screening criteriaExceeds screening criteriaExceeds screening criteriaExceeds screening criteria
34Exceeds screening criteriaExceeds screening criteriaExceeds screening criteriaExceeds screening criteria
35Exceeds screening criteriaExceeds screening criteriaExceeds screening criteriaExceeds screening criteria
36Exceeds screening criteriaExceeds screening criteriaExceeds screening criteriaExceeds screening criteria

Unacclimatized workers

WBGT (°C)Light
180 W
Moderate
300 W
Heavy
415 W
Very heavy
520 W
2475–100% Work75–100% Work50–75% Work25–50% Work
2575–100% Work75–100% Work25–50% Work0–25% Work
2675–100% Work50–75% Work0–25% Work0–25% Work
2775–100% Work25–50% Work0–25% Work0–25% Work
2875–100% Work0–25% Work0–25% WorkExceeds screening criteria
2925–50% Work0–25% WorkExceeds screening criteriaExceeds screening criteria
300–25% WorkExceeds screening criteriaExceeds screening criteriaExceeds screening criteria
31Exceeds screening criteriaExceeds screening criteriaExceeds screening criteriaExceeds screening criteria
32Exceeds screening criteriaExceeds screening criteriaExceeds screening criteriaExceeds screening criteria
33Exceeds screening criteriaExceeds screening criteriaExceeds screening criteriaExceeds screening criteria
34Exceeds screening criteriaExceeds screening criteriaExceeds screening criteriaExceeds screening criteria
35Exceeds screening criteriaExceeds screening criteriaExceeds screening criteriaExceeds screening criteria
36Exceeds screening criteriaExceeds screening criteriaExceeds screening criteriaExceeds screening criteria

Inputs

Required inputs: wbgtC, workload

Optional inputs: acclimatization

Sources

Update history