Heat Rules Worker Heat Safety Beta — under active development, not production-ready. Verify every result against the governing standard.
On this page

← Back to the calculator · All standards

Nevada Wildfire Smoke Protection (SB 260 / NRS 618.297; LCB R070-26, proposed) — Wildfire Smoke Exposure Thresholds (PM2.5 / AQI)

Nevada SB 260 (2025) added NRS 618.297, whose statutory employer duties took effect 2026-01-01, and directed the Administrator of the Division of Industrial Relations to make implementing regulations. The implementing regulation, LCB File R070-26, sets exactly two AQI-for-PM2.5 thresholds: at AQI 150 or above, attributable to wildfire smoke, the employer must implement engineering, administrative and PPE controls, provide NIOSH-approved N95 filtering facepiece respirators for voluntary use, operate a two-way exposure communication system and train employees; at AQI 500 or above the employer must not allow employees to perform the 'critical tasks' identified in its written safety program outdoors. R070-26 IS STILL PROPOSED, NOT ADOPTED — hence legalStatus proposed_rule.

Browse all standards → · Evaluate every standard at once in the calculator →

Governing metric
Air Quality Index for PM2.5 (AQI-PM2.5) specifically, never a composite AQI. PM2.5 in µg/m³ is converted via the calculator's existing EPA breakpoints.
Authority
Division of Industrial Relations, Nevada Department of Business and Industry (Nevada OSHA)
Jurisdiction
Nevada
Legal status
Proposed Rule
Proposed
2026-01-01
Rule type
Smoke Overlay
Standard ID
HGC-135

Check a reading against this rule

This rule has no numeric trigger the calculator evaluates — it states duties and control measures rather than a threshold a reading can be checked against. Its measures are listed below.

Governing formula

No standalone formula is published for this standard; see programmable logic and parameters below.

Wildfire smoke thresholds

No wildfire-smoke engine configuration found for this standard.

Key thresholds

ParameterValue
controlsAndVoluntaryRespiratorAqi150
criticalTaskOutdoorProhibitionAqi500

Exactly two thresholds, which is itself a verified finding: the dossier's open question 3 asked whether an intermediate AQI 200 tier existed, and reading both draft versions end to end resolved it in the negative. Do not add a 200 tier from the NRS 618.297(1)(a) statutory wording — that wording delegates to the Administrator, who regulated both bands with one set of measures.

The AQI 500 figure is a CRITICAL-TASK restriction, not a stop-work threshold: it bars only those tasks the employer has identified as critical in its own written plan, which this calculator cannot know, so it is reported as a duty and never computed as a work stoppage. This is structurally different from Cal/OSHA §5141.1's AQI>500 mandatory-respirator-with-fit-testing mechanism and must not be conflated with it.

Inputs

Required inputs: none

Optional inputs: pm25ugm3, aqiPm25, usStateCode, wildfireSmoke, outdoor

Sources

Update history