← Back to the calculator · All standards

Oregon OSHA Heat Illness Prevention Standard (AO 3-2022) — Heat Stress Work/Rest Limits

Oregon OSHA heat illness prevention standard (AO 3-2022). Heat-index based five-tier work/rest schedule with mandatory shade, hydration, and acclimatization.

Open Oregon OSHA Heat Illness Prevention Standard (AO 3-2022) in the interactive Guidance Wiki →

Authority
Oregon Occupational Safety and Health Division (Oregon OSHA)
Jurisdiction
Oregon State Us
Legal status
Regulation
Rule type
Schedule Engine
Standard ID
HGC-057

Governing formula

No standalone formula is published for this standard; see programmable logic and parameters below.

Work/rest limits

Governing metric: Heat index (°F) — derived from air temperature and relative humidity if not directly measured

Programmable logic: Triggered at heat index ≥80°F. Five tiers: <80°F none; 80–89°F baseline (60/0); 90–94°F 50/10; 95–99°F 40/20; 100–104°F 30/30; ≥105°F 20/40. Impermeable or double-layer PPE advances to the next higher tier. Paid rest breaks in shade; 1 qt/hr hydration minimum.

This standard does not take WBGT as a required input, and publishes no standalone numeric parameter table here; see the governing metric and programmable logic above, and the primary source below.

Inputs

Required inputs: none

Optional inputs: heatIndexC, heatIndexF, airTempC, relativeHumidity, workload, acclimatization, ppe

Sources

Related standards