← Back to the calculator · All standards

US Navy / Marine Corps Ashore Flag Conditions — Heat Stress Work/Rest Limits

US Navy and Marine Corps ashore WBGT flag warning system (NAVMED P-5010 Chapter 3). Defines five flag conditions (White, Green, Yellow, Red, Black) based on WBGT in °F with corresponding work/rest schedules and acclimatization restrictions. Applies to military training, physical fitness activities, and strenuous outdoor work.

Open US Navy / Marine Corps Ashore Flag Conditions in the interactive Guidance Wiki →

Authority
Navy Bureau of Medicine and Surgery (BUMED)
Jurisdiction
Us Military
Legal status
Technical Standard
Rule type
Schedule Engine
Standard ID
HGC-063

Governing formula

No standalone formula is published for this standard; see programmable logic and parameters below.

Work/rest limits

WBGT (°C)Light
180 W
Moderate
300 W
Heavy
415 W
Very heavy
520 W
2460 / 0 min work/rest per hr60 / 0 min work/rest per hr60 / 0 min work/rest per hr60 / 0 min work/rest per hr
2560 / 0 min work/rest per hr60 / 0 min work/rest per hr60 / 0 min work/rest per hr60 / 0 min work/rest per hr
2660 / 0 min work/rest per hr60 / 0 min work/rest per hr60 / 0 min work/rest per hr60 / 0 min work/rest per hr
2760 / 0 min work/rest per hr60 / 0 min work/rest per hr60 / 0 min work/rest per hr60 / 0 min work/rest per hr
2860 / 0 min work/rest per hr60 / 0 min work/rest per hr60 / 0 min work/rest per hr60 / 0 min work/rest per hr
2960 / 0 min work/rest per hr60 / 0 min work/rest per hr60 / 0 min work/rest per hr60 / 0 min work/rest per hr
3045 / 15 min work/rest per hr45 / 15 min work/rest per hr45 / 15 min work/rest per hr45 / 15 min work/rest per hr
3145 / 15 min work/rest per hr45 / 15 min work/rest per hr45 / 15 min work/rest per hr45 / 15 min work/rest per hr
3220 / 40 min work/rest per hr20 / 40 min work/rest per hr20 / 40 min work/rest per hr20 / 40 min work/rest per hr
33Stop workStop workStop workStop work
34Stop workStop workStop workStop work
35Stop workStop workStop workStop work
36Stop workStop workStop workStop work

This standard's declared inputs do not include acclimatization status, so results do not vary by it.

Inputs

Required inputs: wbgtC

Optional inputs: ppe

Sources

Related standards