Tamil Nadu Heat Wave Action Plan (TNSDMA) + BOCW Outdoor-Work Timing Restriction — Stop-Work / Banned-Hours Rule

Combines TNSDMA's 2019 Heat Wave Action Plan (public-health alert overlay, IMD-criteria-triggered) with the Tamil Nadu Labour Department's BOCW outdoor construction work timing restriction (10am-4pm, Notification No. 2/9958/2023, 9 May 2024).

Browse all standards → · Evaluate every standard at once in the calculator →

Governing metric
Maximum ambient temperature (IMD plains absolute-temperature criterion: >=45C heat wave / >=47C severe) for the HAP advisory overlay; calendar/time-of-day only for the BOCW stop-work component
Authority
Tamil Nadu State Disaster Management Authority / Tamil Nadu Labour Department (BOCW)
Jurisdiction
Tamil Nadu India
Legal status
Regulation
In force since
2024-05-09
Rule type
Stop Work Rule
Standard ID
HGC-085

Check a reading against this rule

The drag-to-check calculator needs JavaScript. Every value it can show is a row of the table below, which is computed by the same engine.

Governing formula

No standalone formula is published for this standard; see programmable logic and parameters below.

Stop-work / banned hours

Forecast maximum temperature (°C)Result
35None
36None
37None
38None
39None
40None
41None
42None
43None
44None
45Heat Wave
46Heat Wave
47Severe Heat Wave
48Severe Heat Wave
49Severe Heat Wave
50Severe Heat Wave

Key thresholds

ParameterValue
heatWaveDepartureMinC4.5
severeHeatWaveDepartureMinC6.4
plainsAbsoluteThresholdC40
coastalAbsoluteThresholdC37
hillsAbsoluteThresholdC30
plainsSevereAbsoluteThresholdC47
plainsHeatWaveAbsoluteThresholdC45
hapAdvisoryRestStartHour12
hapAdvisoryRestEndHour15
bocwStopWorkStartHour10
bocwStopWorkEndHour16

Only the plains absolute-temperature criterion (plainsHeatWaveAbsoluteThresholdC / plainsSevereAbsoluteThresholdC) is evaluated by this engine; the coastal, hills, and departure-from-normal figures above are the published IMD criteria reproduced by the TNSDMA HAP but are not computed (no region-type or 'normal' baseline-temperature input exists in this calculator).

The bocwStopWork window (10:00-16:00) is the binding/statutory value for construction work and is the composite-entering stop-work rule; hapAdvisory (12:00-15:00) is general public-health guidance only, not composite-entering. Neither has an annual-reissue date confirmed for Tamil Nadu specifically -- re-verify before treating as a standing rule.