Heat Rules Worker Heat Safety Beta — under active development, not production-ready. Verify every result against the governing standard.
On this page

← Back to the calculator · All standards

Ecuador Norma Técnica de Seguridad e Higiene del Trabajo — Art. 8 Heat (WBGT Ceilings) — Heat Stress Control Measures

Article 8 of Ecuador's Norma Técnica de Seguridad e Higiene del Trabajo sets WBGT exposure ceilings by workload tier and acclimatization state, together with an ordered control hierarchy. Exceeding a ceiling creates a duty to control exposure — the article prescribes no work/rest schedule and no suspension of work.

Browse all standards → · Evaluate every standard at once in the calculator →

Governing metric
WBGT (°C) ceiling by workload tier and acclimatization state
Authority
Ministerio del Trabajo del Ecuador (Acuerdo Ministerial MDT-2024-196, Anexo 3; parent Decreto Ejecutivo Nro. 255)
Jurisdiction
Ecuador
Legal status
Regulation
In force since
2024-05-02 (unverified)
Rule type
Control Overlay
Standard ID
HGC-101

Check a reading against this rule

The drag-to-check calculator needs JavaScript. Every value it can show is a row of the table below, which is computed by the same engine.

Governing formula

No standalone formula is published for this standard; see programmable logic and parameters below.

Control measures

Acclimatized workers

WBGT (°C)Light
180 W
Moderate
300 W
Heavy
415 W
Very heavy
520 W
24Within 30°C ceilingWithin 28°C ceilingWithin 27°C ceilingWithin 27°C ceiling
25Within 30°C ceilingWithin 28°C ceilingWithin 27°C ceilingWithin 27°C ceiling
26Within 30°C ceilingWithin 28°C ceilingWithin 27°C ceilingWithin 27°C ceiling
27Within 30°C ceilingWithin 28°C ceilingWithin 27°C ceilingWithin 27°C ceiling
28Within 30°C ceilingWithin 28°C ceilingExceeds 27°C ceilingExceeds 27°C ceiling
29Within 30°C ceilingExceeds 28°C ceilingExceeds 27°C ceilingExceeds 27°C ceiling
30Within 30°C ceilingExceeds 28°C ceilingExceeds 27°C ceilingExceeds 27°C ceiling
31Exceeds 30°C ceilingExceeds 28°C ceilingExceeds 27°C ceilingExceeds 27°C ceiling
32Exceeds 30°C ceilingExceeds 28°C ceilingExceeds 27°C ceilingExceeds 27°C ceiling
33Exceeds 30°C ceilingExceeds 28°C ceilingExceeds 27°C ceilingExceeds 27°C ceiling
34Exceeds 30°C ceilingExceeds 28°C ceilingExceeds 27°C ceilingExceeds 27°C ceiling
35Exceeds 30°C ceilingExceeds 28°C ceilingExceeds 27°C ceilingExceeds 27°C ceiling
36Exceeds 30°C ceilingExceeds 28°C ceilingExceeds 27°C ceilingExceeds 27°C ceiling

Unacclimatized workers

WBGT (°C)Light
180 W
Moderate
300 W
Heavy
415 W
Very heavy
520 W
24Within 28°C ceilingWithin 26°C ceilingWithin 25°C ceilingWithin 25°C ceiling
25Within 28°C ceilingWithin 26°C ceilingWithin 25°C ceilingWithin 25°C ceiling
26Within 28°C ceilingWithin 26°C ceilingExceeds 25°C ceilingExceeds 25°C ceiling
27Within 28°C ceilingExceeds 26°C ceilingExceeds 25°C ceilingExceeds 25°C ceiling
28Within 28°C ceilingExceeds 26°C ceilingExceeds 25°C ceilingExceeds 25°C ceiling
29Exceeds 28°C ceilingExceeds 26°C ceilingExceeds 25°C ceilingExceeds 25°C ceiling
30Exceeds 28°C ceilingExceeds 26°C ceilingExceeds 25°C ceilingExceeds 25°C ceiling
31Exceeds 28°C ceilingExceeds 26°C ceilingExceeds 25°C ceilingExceeds 25°C ceiling
32Exceeds 28°C ceilingExceeds 26°C ceilingExceeds 25°C ceilingExceeds 25°C ceiling
33Exceeds 28°C ceilingExceeds 26°C ceilingExceeds 25°C ceilingExceeds 25°C ceiling
34Exceeds 28°C ceilingExceeds 26°C ceilingExceeds 25°C ceilingExceeds 25°C ceiling
35Exceeds 28°C ceilingExceeds 26°C ceilingExceeds 25°C ceilingExceeds 25°C ceiling
36Exceeds 28°C ceilingExceeds 26°C ceilingExceeds 25°C ceilingExceeds 25°C ceiling

Key thresholds

ParameterValue
wbgtCeilingC
  • light unacclimatized 28, acclimatized 30
  • moderate unacclimatized 26, acclimatized 28
  • heavy unacclimatized 25, acclimatized 27
airCirculationMaxAirTempC35

35°C is a precondition on the air-circulation engineering control in Art. 8 §1.c.i ('cuando la temperatura del aire sea inferior a 35 °C'), scoped to dry-bulb air temperature.

It is NOT an exposure ceiling, NOT an alert level and NOT a stop-work trigger, and it must never be compared against WBGT. Three further deliberate omissions, all source gaps rather than encoding gaps: Art. 8 §1.d.i requires 'pausas regulares' without specifying any quantity, so no minutes are computed; §1.d.vi requires sufficient potable water without stating a litres/hour figure; and 'no aclimatados' is used throughout but never defined (only the positive term 'Trabajos aclimatados' is defined, in Art. 3 item 32, with no day-count criterion).

The six ceilings are not equal to the ACGIH TLV action-limit/TLV pairs, so no ACGIH or ISO 7243 derivation is asserted.

Inputs

Required inputs: wbgtC, workload

Optional inputs: acclimatization, airTempC

Sources

Update history