Article 8 of Ecuador's Norma Técnica de Seguridad e Higiene del Trabajo sets WBGT exposure ceilings by workload tier and acclimatization state, together with an ordered control hierarchy. Exceeding a ceiling creates a duty to control exposure — the article prescribes no work/rest schedule and no suspension of work.
Browse all standards → · Evaluate every standard at once in the calculator →
The drag-to-check calculator needs JavaScript. Every value it can show is a row of the table below, which is computed by the same engine.
No standalone formula is published for this standard; see programmable logic and parameters below.
| WBGT (°C) | Light 180 W | Moderate 300 W | Heavy 415 W | Very heavy 520 W |
|---|---|---|---|---|
| 24 | Within 30°C ceiling | Within 28°C ceiling | Within 27°C ceiling | Within 27°C ceiling |
| 25 | Within 30°C ceiling | Within 28°C ceiling | Within 27°C ceiling | Within 27°C ceiling |
| 26 | Within 30°C ceiling | Within 28°C ceiling | Within 27°C ceiling | Within 27°C ceiling |
| 27 | Within 30°C ceiling | Within 28°C ceiling | Within 27°C ceiling | Within 27°C ceiling |
| 28 | Within 30°C ceiling | Within 28°C ceiling | Exceeds 27°C ceiling | Exceeds 27°C ceiling |
| 29 | Within 30°C ceiling | Exceeds 28°C ceiling | Exceeds 27°C ceiling | Exceeds 27°C ceiling |
| 30 | Within 30°C ceiling | Exceeds 28°C ceiling | Exceeds 27°C ceiling | Exceeds 27°C ceiling |
| 31 | Exceeds 30°C ceiling | Exceeds 28°C ceiling | Exceeds 27°C ceiling | Exceeds 27°C ceiling |
| 32 | Exceeds 30°C ceiling | Exceeds 28°C ceiling | Exceeds 27°C ceiling | Exceeds 27°C ceiling |
| 33 | Exceeds 30°C ceiling | Exceeds 28°C ceiling | Exceeds 27°C ceiling | Exceeds 27°C ceiling |
| 34 | Exceeds 30°C ceiling | Exceeds 28°C ceiling | Exceeds 27°C ceiling | Exceeds 27°C ceiling |
| 35 | Exceeds 30°C ceiling | Exceeds 28°C ceiling | Exceeds 27°C ceiling | Exceeds 27°C ceiling |
| 36 | Exceeds 30°C ceiling | Exceeds 28°C ceiling | Exceeds 27°C ceiling | Exceeds 27°C ceiling |
| WBGT (°C) | Light 180 W | Moderate 300 W | Heavy 415 W | Very heavy 520 W |
|---|---|---|---|---|
| 24 | Within 28°C ceiling | Within 26°C ceiling | Within 25°C ceiling | Within 25°C ceiling |
| 25 | Within 28°C ceiling | Within 26°C ceiling | Within 25°C ceiling | Within 25°C ceiling |
| 26 | Within 28°C ceiling | Within 26°C ceiling | Exceeds 25°C ceiling | Exceeds 25°C ceiling |
| 27 | Within 28°C ceiling | Exceeds 26°C ceiling | Exceeds 25°C ceiling | Exceeds 25°C ceiling |
| 28 | Within 28°C ceiling | Exceeds 26°C ceiling | Exceeds 25°C ceiling | Exceeds 25°C ceiling |
| 29 | Exceeds 28°C ceiling | Exceeds 26°C ceiling | Exceeds 25°C ceiling | Exceeds 25°C ceiling |
| 30 | Exceeds 28°C ceiling | Exceeds 26°C ceiling | Exceeds 25°C ceiling | Exceeds 25°C ceiling |
| 31 | Exceeds 28°C ceiling | Exceeds 26°C ceiling | Exceeds 25°C ceiling | Exceeds 25°C ceiling |
| 32 | Exceeds 28°C ceiling | Exceeds 26°C ceiling | Exceeds 25°C ceiling | Exceeds 25°C ceiling |
| 33 | Exceeds 28°C ceiling | Exceeds 26°C ceiling | Exceeds 25°C ceiling | Exceeds 25°C ceiling |
| 34 | Exceeds 28°C ceiling | Exceeds 26°C ceiling | Exceeds 25°C ceiling | Exceeds 25°C ceiling |
| 35 | Exceeds 28°C ceiling | Exceeds 26°C ceiling | Exceeds 25°C ceiling | Exceeds 25°C ceiling |
| 36 | Exceeds 28°C ceiling | Exceeds 26°C ceiling | Exceeds 25°C ceiling | Exceeds 25°C ceiling |
| Parameter | Value |
|---|---|
wbgtCeilingC |
|
airCirculationMaxAirTempC | 35 |
35°C is a precondition on the air-circulation engineering control in Art. 8 §1.c.i ('cuando la temperatura del aire sea inferior a 35 °C'), scoped to dry-bulb air temperature.
It is NOT an exposure ceiling, NOT an alert level and NOT a stop-work trigger, and it must never be compared against WBGT. Three further deliberate omissions, all source gaps rather than encoding gaps: Art. 8 §1.d.i requires 'pausas regulares' without specifying any quantity, so no minutes are computed; §1.d.vi requires sufficient potable water without stating a litres/hour figure; and 'no aclimatados' is used throughout but never defined (only the positive term 'Trabajos aclimatados' is defined, in Art. 3 item 32, with no day-count criterion).
The six ceilings are not equal to the ACGIH TLV action-limit/TLV pairs, so no ACGIH or ISO 7243 derivation is asserted.
Required inputs: wbgtC, workload
Optional inputs: acclimatization, airTempC
This standard was added to the calculator.
Get notified when Ecuador Norma Técnica de Seguridad e Higiene del Trabajo — Art. 8 Heat (WBGT Ceilings) changes — threshold changes, scope and legal-status changes, additions and removals. Changes that permit more heat exposure than before are labelled as such.
Paste this address into any feed reader:
https://heatrules.com/standards/ecuador_norma_tecnica_calor/feed.xml
Open the feed · All update feeds · No account or email address is needed; the site keeps no subscriber list.