Hungary 3/2002 SzCsM-EüM — Minimum Health and Safety Requirements for Workplaces (Climate Provisions) — Heat Stress Control Measures

3/2002. SzCsM-EüM együttes rendelet sets, in its 2. számú melléklet (climate annex), a maximum permissible corrected effective / effective temperature (KEH/EH) by work category, plus a warm-season air-temperature advisory range. Separately, §7 sets a paid rest-break duty (§7(8)) and a protective-drink duty (§7(10)) that apply whenever a workplace meets the §7(8a) legal definition of a "hot workplace" (melegnek minősülő munkahely), inserted by 63/2023. (XII. 28.) GFM rendelet §1(1), eff. 2024-01-01. These are two independent legal tests on two different thresholds and are never blended.

Browse all standards → · Evaluate every standard at once in the calculator →

Governing metric
Corrected effective temperature (KEH) — or effective temperature (EH) when radiant load is not significant — read off a nomogram from air temperature, relative humidity and air velocity (globe-thermometer-based once radiant load is significant, per 1.2). Distinct from WBGT, psychrometric wet-bulb, and operative temperature (the Czech/Slovak metric); this app has no nomogram, so correctedEffectiveTempC is a caller-supplied value.
Authority
Szociális és Családügyi Minisztérium (SzCsM) / Egészségügyi Minisztérium (EüM), Hungary; §7(8a)/(8b) inserted by 63/2023. (XII. 28.) GFM rendelet, Gazdaságfejlesztési Minisztérium
Jurisdiction
Hungary
Legal status
Regulation
In force since
2002-02-08 (unverified)
Rule type
Control Overlay
Standard ID
HGC-111

Check a reading against this rule

This rule has no numeric trigger the calculator evaluates — it states duties and control measures rather than a threshold a reading can be checked against. Its measures are listed below.

Governing formula

No standalone formula is published for this standard; see programmable logic and parameters below.

Control measures

ParameterValue
kehMaxMentalC31
kehMaxLightC31
kehMaxMediumC29
kehMaxHeavyC27
warmSeasonAirTempMinMentalC21
warmSeasonAirTempMaxMentalC24
warmSeasonAirTempMinLightC19
warmSeasonAirTempMaxLightC21
warmSeasonAirTempMinMediumC17
warmSeasonAirTempMaxMediumC19
warmSeasonAirTempMinHeavyC15
warmSeasonAirTempMaxHeavyC17
kehTriggerDeltaC5
acclimatizationProximityBandC1
acclimatizationPeriodWeeks1
protectiveDrinkMinFrequencyMin30
protectiveDrinkTempMinC14
protectiveDrinkTempMaxC16
protectiveDrinkMaxSugarPct4
paidRestBreakMinMin5
paidRestBreakMaxMin10
hotWorkplaceIndoorKehC24
hotWorkplaceOutdoorDailyMeanC25
highRadiantHeatMultiplier3

kehMaxMentalC / warmSeasonAirTempMin/MaxMentalC are recorded for citation completeness but are never reached by this engine's workload mapping: the app's workload vocabulary has no 'mental work' category distinct from light physical work, and since Szellemi munka and Könnyű fizikai munka share an identical 31°C ceiling, the collapse costs no precision on the ceiling actually screened. warmSeasonAirTempMin/Max* (2. sz. melléklet col. 3) are reference-only advisory ranges, not gated — this engine screens KEH/EH (col. 5), not raw dry-bulb air temperature. hotWorkplaceOutdoorDailyMeanC (§7(8a)) is likewise reference-only: the outdoor 'hot workplace' test also requires a national chief medical officer heat warning/alert on top of the sustained daily mean, and this calculator has no daily-mean time-series input, so the full outdoor test is folded into the single caller-supplied hungaryHeatAlertActive flag rather than computed from dailyMeanTempC in-app.

DELIBERATELY NOT ENCODED: the 45 min/hour break escalation at 32.5°C (not found anywhere in the retrieved primary text, single-source/uncorroborated); cold-season air-temperature ranges (2. sz. melléklet col. 2: 20-22/18-20/14-18/12-14°C), out of scope for a heat engine; §7(8b)'s cold-workplace definition (+4°C outdoor / +10°C indoor daily mean), cold-side and out of scope; 2. sz. melléklet col. 4's warm-season EH/KEH target values (20/19/15/13°C) — quotable and verified, but out of this engine's requested scope (cols. 3 and 5 only); 97/2026 (VI. 25.) Korm. rendelet's specific numeric content, not independently re-verified this session; and 1. számú melléklet's minimum air-volume-per-worker figures, a ventilation requirement, not a heat threshold.

No stop-work is encoded: nothing in the retrieved primary text prescribes one.

Programmable logic

2. sz. melléklet 1. táblázat col. 5 sets the ceiling: 31°C for mental work (Szellemi munka) and light physical work (Könnyű fizikai munka, which share an identical ceiling), 29°C for medium physical work (Közepesen nehéz fizikai munka), 27°C for heavy physical work (Nehéz fizikai munka).

The app's workload vocabulary has no distinct 'mental work' category, so it maps to the light-work ceiling — costless, since the two ceilings are identical. Col. 3 gives a warm-season air-temperature advisory range per category (reference only; not gated, since the engine screens KEH/EH, not raw air temperature).

1.2 sets a 5°C globe-minus-dry-bulb trigger for using the globe-based KEH instead of EH; §7(7) separately classifies radiant heat as 'high-degree' (nagyfokú) above 3x that delta (15°C) — both surfaced as informational flags. 1.3 requires 1 week of gradual acclimatization for full-shift exposure once KEH/EH is at or within 1°C of the ceiling.

Independently, §7(8a) defines a 'hot workplace': indoor KEH/EH above 24°C, or outdoor a >25°C daily mean sustained >=1 day plus a national chief medical officer heat warning/alert — the outdoor branch is folded into a single caller-supplied hungaryHeatAlertActive flag, since this calculator has no daily-mean time-series input.

A hot workplace triggers §7(8) (5-10 minutes of paid rest per hour) and §7(10) (a protective drink at least every 30 minutes, 14-16°C water or a <=4%-sugar flavored non-alcoholic drink at the same temperature). No work/rest minutes and no stop-work are produced.