Heat Rules Worker Heat Safety Beta — under active development, not production-ready. Verify every result against the governing standard.
On this page

← Back to the calculator · All standards

Uruguay MTSS — Guía para trabajos con exposición a altas temperaturas (2025) — Heat Stress Control Measures

MTSS 'Guía para trabajos con exposición a altas temperaturas' (November 2025) publishes an advisory reference table of recommended indoor air temperature and relative-humidity bands for enclosed or interior workplaces, alongside a duty to develop a site-specific heat protocol and integrate it into the prevention plan. This engine encodes only those indoor temperature/relative-humidity reference bands as an advisory control overlay; the guide's other attachments (a graded WBGT exposure ladder, the SINAE/INUMET heat-alert scale and a heat-index table) are deliberately NOT encoded here. No work/rest minutes and no stop-work are produced.

Browse all standards → · Evaluate every standard at once in the calculator →

Governing metric
Indoor dry-bulb air temperature (°C) and relative humidity (%)
Authority
Ministerio de Trabajo y Seguridad Social (MTSS), Uruguay
Jurisdiction
Uruguay
Legal status
Guidance
Published
2025-11-04
Rule type
Control Overlay
Standard ID
HGC-123

Check a reading against this rule

This rule has no numeric trigger the calculator evaluates — it states duties and control measures rather than a threshold a reading can be checked against. Its measures are listed below.

Governing formula

inRecommendedBand = indoorTempC within 17–27 °C and relativeHumidity within 30–70 %

Control measures

ParameterValue
generalTempMinC17
generalTempMaxC27
generalRhMinPct30
generalRhMaxPct70
indoorReferenceBandstaskKey general, tempMinC 17, tempMaxC 27, rhMinPct 30, rhMaxPct 70, taskKey sedentary_winter, tempMinC 20, tempMaxC 24, rhMinPct 40, rhMaxPct 60, taskKey sedentary_summer, tempMinC 23, tempMaxC 26, rhMinPct 40, rhMaxPct 60, taskKey moderate, tempMinC 18, tempMaxC 25, rhMinPct 40, rhMaxPct 70, taskKey intense, tempMaxC 30, rhMinPct 30, rhMaxPct 60, taskKey climate_controlled, tempMinC 20, tempMaxC 22, rhMinPct 45, rhMaxPct 55

Programmable logic

Advisory comparison of an indoor reading against the guide's general enclosed-workplace band of 17–27 °C and 30–70% relative humidity. The guide's other task-specific bands (sedentary light tasks 20–24 °C winter / 23–26 °C summer at 40–60%; moderate tasks 18–25 °C at 40–70%; physically intense tasks or heat sources up to 30 °C at 30–60%; climate-controlled areas 20–22 °C at 45–55%) are surfaced as reference controls.

The protocol duties from the guide's text (develop a task-specific protocol, integrate it into the prevention plan, involve workers, identify exposed tasks/time/persons, adopt ventilation/breaks/hydration/clothing/critical-hour measures, sign and validate, use the reference table, update periodically) are emitted as controls. No work/rest minutes are generated and stopWork is always false.

Inputs

Required inputs: none

Optional inputs: indoorTempC, relativeHumidity