Heat Rules Worker Heat Safety Beta — under active development, not production-ready. Verify every result against the governing standard.
On this page

← Back to the calculator · All standards

Bangladesh Labour Rules 2015 (Schedule-I) — Heat Stress Screening Thresholds

Bangladesh Labour Rules schedule using wet-bulb and dry-bulb relationships for permissible humidity conditions.

Browse all standards → · Evaluate every standard at once in the calculator →

Governing metric
Dry-bulb and wet-bulb temperature
Authority
Bangladesh Ministry of Labour and Employment
Jurisdiction
Bangladesh
Legal status
Regulation
In force since
2015-09-15 (unverified)
Rule type
Screening Limit
Standard ID
HGC-024

Check a reading against this rule

The drag-to-check calculator needs JavaScript. Every value it can show is a row of the table below, which is computed by the same engine.

Governing formula

No standalone formula is published for this standard; see programmable logic and parameters below.

Screening thresholds

Dry bulb (°C)16°C WB18°C WB20°C WB22°C WB24°C WB26°C WB28°C WB30°C WB32°C WB
18Within limit (≤16.9°C wet-bulb)Exceeds limit (>16.9°C wet-bulb)Exceeds limit (>16.9°C wet-bulb)Exceeds limit (>16.9°C wet-bulb)Exceeds limit (>16.9°C wet-bulb)Exceeds limit (>16.9°C wet-bulb)Exceeds limit (>16.9°C wet-bulb)Exceeds limit (>16.9°C wet-bulb)Exceeds limit (>16.9°C wet-bulb)
20Within limit (≤18.9°C wet-bulb)Within limit (≤18.9°C wet-bulb)Exceeds limit (>18.9°C wet-bulb)Exceeds limit (>18.9°C wet-bulb)Exceeds limit (>18.9°C wet-bulb)Exceeds limit (>18.9°C wet-bulb)Exceeds limit (>18.9°C wet-bulb)Exceeds limit (>18.9°C wet-bulb)Exceeds limit (>18.9°C wet-bulb)
22Within limit (≤20.9°C wet-bulb)Within limit (≤20.9°C wet-bulb)Within limit (≤20.9°C wet-bulb)Exceeds limit (>20.9°C wet-bulb)Exceeds limit (>20.9°C wet-bulb)Exceeds limit (>20.9°C wet-bulb)Exceeds limit (>20.9°C wet-bulb)Exceeds limit (>20.9°C wet-bulb)Exceeds limit (>20.9°C wet-bulb)
24Within limit (≤22.9°C wet-bulb)Within limit (≤22.9°C wet-bulb)Within limit (≤22.9°C wet-bulb)Within limit (≤22.9°C wet-bulb)Exceeds limit (>22.9°C wet-bulb)Exceeds limit (>22.9°C wet-bulb)Exceeds limit (>22.9°C wet-bulb)Exceeds limit (>22.9°C wet-bulb)Exceeds limit (>22.9°C wet-bulb)
26Within limit (≤24.9°C wet-bulb)Within limit (≤24.9°C wet-bulb)Within limit (≤24.9°C wet-bulb)Within limit (≤24.9°C wet-bulb)Within limit (≤24.9°C wet-bulb)Exceeds limit (>24.9°C wet-bulb)Exceeds limit (>24.9°C wet-bulb)Exceeds limit (>24.9°C wet-bulb)Exceeds limit (>24.9°C wet-bulb)
28Within limit (≤26.8°C wet-bulb)Within limit (≤26.8°C wet-bulb)Within limit (≤26.8°C wet-bulb)Within limit (≤26.8°C wet-bulb)Within limit (≤26.8°C wet-bulb)Within limit (≤26.8°C wet-bulb)Exceeds limit (>26.8°C wet-bulb)Exceeds limit (>26.8°C wet-bulb)Exceeds limit (>26.8°C wet-bulb)
30Within limit (≤28°C wet-bulb)Within limit (≤28°C wet-bulb)Within limit (≤28°C wet-bulb)Within limit (≤28°C wet-bulb)Within limit (≤28°C wet-bulb)Within limit (≤28°C wet-bulb)Within limit (≤28°C wet-bulb)Exceeds limit (>28°C wet-bulb)Exceeds limit (>28°C wet-bulb)
32Within limit (≤29.1°C wet-bulb)Within limit (≤29.1°C wet-bulb)Within limit (≤29.1°C wet-bulb)Within limit (≤29.1°C wet-bulb)Within limit (≤29.1°C wet-bulb)Within limit (≤29.1°C wet-bulb)Within limit (≤29.1°C wet-bulb)Exceeds limit (>29.1°C wet-bulb)Exceeds limit (>29.1°C wet-bulb)
34Within limit (≤30°C wet-bulb)Within limit (≤30°C wet-bulb)Within limit (≤30°C wet-bulb)Within limit (≤30°C wet-bulb)Within limit (≤30°C wet-bulb)Within limit (≤30°C wet-bulb)Within limit (≤30°C wet-bulb)Within limit (≤30°C wet-bulb)Exceeds limit (>30°C wet-bulb)
36Within limit (≤31°C wet-bulb)Within limit (≤31°C wet-bulb)Within limit (≤31°C wet-bulb)Within limit (≤31°C wet-bulb)Within limit (≤31°C wet-bulb)Within limit (≤31°C wet-bulb)Within limit (≤31°C wet-bulb)Within limit (≤31°C wet-bulb)Exceeds limit (>31°C wet-bulb)
38Within limit (≤32°C wet-bulb)Within limit (≤32°C wet-bulb)Within limit (≤32°C wet-bulb)Within limit (≤32°C wet-bulb)Within limit (≤32°C wet-bulb)Within limit (≤32°C wet-bulb)Within limit (≤32°C wet-bulb)Within limit (≤32°C wet-bulb)Exceeds limit (>32°C wet-bulb)

Inputs

Required inputs: airTempC, wetBulbC

Optional inputs: none

Sources

Update history