Japan 労働安全衛生規則 (Industrial Safety and Health Regulations) Art. 611-612 — underground workplace air temperature — Heat Stress Screening Thresholds

労働安全衛生規則 (Ministry of Labour Ordinance No. 32 of 1972) Art. 611: the employer must keep the air temperature in underground workings at or below 37 °C, except for rescue or hazard-prevention work carried out with the health measures needed against high temperature. Art. 612: air temperature at underground workplaces must be measured at least once every half month.

Browse all standards → · Evaluate every standard at once in the calculator →

Governing metric
Underground workplace air temperature (°C)
Authority
Ministry of Health, Labour and Welfare, Japan (厚生労働省)
Jurisdiction
Japan Underground Workplaces
Legal status
Regulation
In force since
1972-09-30
Rule type
Screening Limit
Standard ID
HGC-151

Check a reading against this rule

This rule has no numeric trigger the calculator evaluates — it states duties and control measures rather than a threshold a reading can be checked against. Its measures are listed below.

Governing formula

No standalone formula is published for this standard; see programmable logic and parameters below.

Screening thresholds

ParameterValue
maxAirTempC37
measurementIntervalDays15

Programmable logic

airTempC > 37: ceiling exceeded; the employer is in breach of Art. 611 unless the rescue/hazard-prevention proviso applies with health measures. Exactly 37 °C complies. Screening limit only: no work/rest schedule or stop-work trigger. Applies to underground workplaces (industry mining). The Mine Safety Act Enforcement Regulations Art. 16 counterpart was not read and is not modelled.

Inputs

Required inputs: airTempC

Optional inputs: none