Kazakhstan Hygienic Standards for Physical Factors — ТНС-index Limits (Order ДСМ-15, 2022) — Heat Stress Screening Thresholds

Hygienic Standards for physical factors (Order of the Minister of Health ДСМ-15 of 16.02.2022), Table 3: permissible upper-bound ТНС-index (WBGT-equivalent) by work category, for heated-microclimate workplaces year-round and for open territory in the warm season when air temperature is above +25 °C.

Browse all standards → · Evaluate every standard at once in the calculator →

Governing metric
ТНС-index (WBGT-equivalent, °C) by energy-expenditure category (W/m²)
Authority
Ministry of Health of the Republic of Kazakhstan
Jurisdiction
Kazakhstan
Legal status
Regulation
In force since
2022-02-16 (unverified)
Rule type
Screening Limit
Standard ID
HGC-160

Check a reading against this rule

The drag-to-check calculator needs JavaScript. Every value it can show is a row of the table below, which is computed by the same engine.

Governing formula

No standalone formula is published for this standard; see programmable logic and parameters below.

Screening thresholds

ParameterValue
catIaLimitC26.4
catIbLimitC25.8
catIIaLimitC25.1
catIIbLimitC23.9
catIIILimitC21.8
outdoorAboveAirTempC25

Programmable logic

Energy expenditure is metabolicRateW divided by an assumed 1.8 m² body surface, then banded: Ia up to 77 W/m² limit 26.4; Ib up to 97 limit 25.8; IIa up to 129 limit 25.1; IIb up to 160 limit 23.9; III above that (open-ended, so heavy and very heavy work take the strictest limit) 21.8 °C. A value between two published bands takes the next, stricter category.